Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.rights.license | https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es | |
dc.creator | San Esteban, Jair Lazarín | |
dc.date.accessioned | 2025-07-04T23:46:51Z | - |
dc.date.available | 2025-07-04T23:46:51Z | - |
dc.date.issued | 2014 | |
dc.identifier.issn | 2395-9215 | |
dc.identifier.uri | https://ru.odonto.unam.mx/handle/123456789/32490 | - |
dc.description.abstract | Introduction: Cleft lip and palate (CLP) is the most frequent craniofacial defect. (1:1000 newborns). CLP patients present severe maxillary retrusion that require a surgical procedure to advance their maxilla. Distraction osteogenesis is an effective treatment; however available internal maxillary distraction devices present inconveniences. Objective: To design a biocompatible, inexpensive and mechanically efficient prototype of an internal maxillary distraction device. This device should be easy to place and comfortable for the patient. Method: Computed tomography (CT) data of an adult CLP patient was obtained. DICOM files were processed and a stereolitographic (STL) model was printed. Computer aided design (CAD) software was used to design the device and to perform a fi nite element analysis (FEA) to evaluate the mechanical behavior of the appliance. Finally a prototype was manufactured by a computer aided manufacturing (CAM) process and tested on the STL model. Results: This prototype complied with our requirements for an effi cient internal maxillary distraction device. Conclusions: The integration of clinical knowledge with novel technology (CT, STL, CAD, FEA, and CAM) is very useful for the development of medical or dental appliances.Key words: Distraction osteogenesis, fi nite element analysis, cleft lip and palate. | |
dc.language | eng | |
dc.publisher | Universidad Nacional Autónoma de México. Facultad de Odontología | |
dc.rights | La titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC-ND 4.0 Internacional, https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es, fecha de asignación de la licencia 2016-02-02, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico revistamexicanadeortodoncia@gmail.com | |
dc.subject.classification | Ciencias Biológicas, Químicas y de la Salud | |
dc.title | Design of an internal distraction device for maxillary advancement in cleft-lip-palate patients | |
dc.type | Artículo Técnico-Profesional | |
dcterms.provenance | Universidad Nacional Autónoma de México. Facultad de Odontología | |
dc.description.repository | Repositorio Universitario de la Facultad de Odontología, https://ru.odonto.unam.mx/ Facultad Odontología | |
dc.rights.accessrights | Acceso abierto | |
dc.identifier.url | https://revistas.unam.mx/index.php/rmo/article/view/54182/48219 | |
dc.identifier.bibliographiccitation | San Esteban, Jair Lazarín (2014). Design of an internal distraction device for maxillary advancement in cleft-lip-palate patients. Revista Mexicana de Ortodoncia; Vol. 2 Núm. 3, 2014. | |
dc.identifier.doi | https://doi.org/10.1016/S2395-9215(16)30142-8 | |
dc.relation.ispartofjournal | Revista Mexicana de Ortodoncia; Vol. 2 Núm. 3 (2014) | |
Aparece en las colecciones: | Revistas |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.