Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licensehttps://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es-
dc.creatorMartínez Pérez, Laura Elizabeth-
dc.date.accessioned2025-01-29T00:11:56Z-
dc.date.available2025-01-29T00:11:56Z-
dc.date.issued2014-
dc.identifier.issn2395-9215-
dc.identifier.urihttps://ru.odonto.unam.mx/handle/123456789/32159-
dc.description.abstractObjective: The purpose of this study was to determine the quality of the size of 0.018” x 0.025” slots in brackets of three trading companies (3M, GAC and ORMCO). Methods: 120 first premolar stainless steel brackets of three trading houses were analyzed forming three groups of 40 brackets. Each bracket was observed under a Profile Projector Microscope. Three measurements were obtained for each slot: depth, internal and external height. The data were tabulated and statistically analyzed by the ANOVA test and the Student’s t test. Results: The results showed that there were statistically significant differences in depth and internal and external height between the bracket’s slot of 3 different companies (p < 0.05). The companies 3M and GAC fulfilled the manufacturer’s specifications (p < 0.05). In terms of internal height, GAC complied with the manufacturer’s specifications (p < 0.05). In relation to external height, ORMCO complied with what is specified by the manufacturer (p < 0.05).Key words: Slot tolerance, slot depth, internal height of the slot, external height of the slot-
dc.languageeng-
dc.publisherUniversidad Nacional Autónoma de México. Facultad de Odontología-
dc.rightsLa titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC-ND 4.0 Internacional, https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es, fecha de asignación de la licencia 2016-01-29, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico revistamexicanadeortodoncia@gmail.com-
dc.subject.classificationCiencias Biológicas, Químicas y de la Salud-
dc.titleSlot tolerance from three different commercial brands of brackets-
dc.typeArtículo Técnico-Profesional-
dcterms.provenanceUniversidad Nacional Autónoma de México. Facultad de Odontología-
dc.description.repositoryRepositorio Universitario de la Facultad de Odontología, https://ru.odonto.unam.mx/ Facultad Odontología-
dc.rights.accessrightsAcceso abierto-
dc.identifier.urlhttps://revistas.unam.mx/index.php/rmo/article/view/54137/48178-
dc.identifier.bibliographiccitationMartínez Pérez, Laura Elizabeth (2014). Slot tolerance from three different commercial brands of brackets. Revista Mexicana de Ortodoncia; Vol. 2 Núm. 1, 2014.-
dc.identifier.doihttps://doi.org/10.1016/S2395-9215(16)30128-3-
dc.relation.ispartofjournalRevista Mexicana de Ortodoncia; Vol. 2 Núm. 1 (2014)-
Aparece en las colecciones: Revistas



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.