Título
Comparación de la profundidad de curado a tres distancias de luz emitida por diodos (LED) con tres colores de resina compuesta
Otros títulos
Comparison of Depth of Cure at Three LED Light Distances with Three Colors of Composite Resin
Autor(es)
Rodríguez-Chávez, Jacqueline Adelina
Flores-Ledesma, Abigailt
Fierro-Ruelas, Geovany
Vargas-Santana, Francisco
Flores-Ruiz, Hugo M
Magaña-Curiel, Karina
Curiel-González, Ricardo
Fecha
2023
Tipo de recurso
Artículo Técnico-Profesional
Dirección electrónica del recurso digital
Entidad del repositorio
Universidad Nacional Autónoma de México. Facultad de Odontología
Resumen
Introduction: If the resin does not receive enough photons at the appropriate wavelengths, the degree of polymerization will be inadequate. There may be greater wear and microleakage, less hardness, and decreased elastic modulus, which can cause pigmentation, postoperative sensitivity, and caries recurrence. Objective: To compare the depth of cure (dc) of the composite resin in shades A1, A2, and A3 at 0 mm, 5 mm, and 10 mm distance with light emitted by diodes (led). Materials and methods: 180 samples in 9 groups (n=20). BrilliantTM NG, Coltene composite resin was used. A1, A2, and A3 at 0 mm (control group), 5 mm, and 10 mm distance of light curing with led lamp (3M Elipar Deep Cure) for 20 s according to the manufacturer"s instructions. Following the test method of the une-en-iso 4049-2019 standard, the non-polymerized material was removed with a plastic spatula. dc (mm) was obtained with a micrometer with an accuracy of ±0.1mm. Results: The depth of cure at a distance of 0 mm of the A1 composite was greater (2.89 mm) compared to the A2 and A3 groups with 2.86 and 2.83 mm respectively, (anova p<0.001). At a distance of 5 mm, the dc of the composite resin A1 was 2.77mm, while with shade A2 it was 2.47mm and A3 was 2.37mm (anova p<0.001. At a distance of 10 mm, the resin A1 obtained a PC of 2.65mm compared to 2.37mm in A2 and 2.23mm in A3 (anova p<0.001). Conclusions: As the distance between the light source and the resin increases, the dc is affected. Therefore, inadvertently moving the light source away from the composite negatively affects curing, reducing the quality and longevity of the material in the mouth.
URI
metadata.dc.identifier.bibliographiccitation
Rodríguez-Chávez, Jacqueline Adelina, et al. (2023). Comparación de la profundidad de curado a tres distancias de luz emitida por diodos (LED) con tres colores de resina compuesta. Revista Odontológica Mexicana Órgano Oficial de la Facultad de Odontología UNAM; Vol. 27 Núm. 2, 2023.
Derechos
La titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC-ND 4.0 Internacional, https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es, fecha de asignación de la licencia 2024-11-11, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico revodontologicamexicana@gmail.com
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.